3.3 6R 1600 B40S 50Hz engine data, optimized emissions
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model
6R1600B
40S
Application group
3B
Intake air temperature
°C
25
Barometric pressure
mbar
1000
Site altitude above sea level
m
100
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number of cylinders
6
Rated engine speed
A rpm
1500
Continuous power ISO 3046 (10% overload capability, design power DIN
6280, ISO 8528)
A kW
274
GENERAL CONDITIONS (for maximum power)
Number of cylinders
6
Intake depression (new filter)
A mbar
25
Intake depression, max.
L mbar
50
Exhaust overpressure
A mbar
85
Exhaust overpressure, max.
L mbar
150
MODEL RELATED DATA (basic design)
Number of cylinders
6
Number of cylinders
6
Standard housing connecting flange (engine main PTO)
SAE
01
Flywheel interface (DISC)
14"
COOLANT SYSTEM (HT circuit)
Number of cylinders
6
Coolant temperature (at engine connection: outlet to cooling system)
A °C
95
Coolant temperature after engine, warning
R °C
105
Coolant temperature after engine, shutdown
L °C
109
MS15022/02E 2012-04 | Technical Data | 25
TIM-ID: 0000026257 - 001