4.5 Engine – Stopping in manual mode
Preconditions
☑
Engine is not under load.
☑
Engine is running in manual mode.
NOTICE
Stopping the engine when it is running at full load subjects it to extreme thermal and mechanical
stresses.
Overheating of and, therefore, damage to components is possible!
• Before shutting down the engine, allow it to idle until the engine temperatures decrease and
constant levels are indicated.
Preparation
Item
Measure
Engine
Operate engine at idling speed for approx. 5 minutes.
Stop engine
Item
Measure
Switch cabinet, operator
station etc. (depending on
manufacturer)
Press stop button.
•
Automatic stopping sequence is executed.
34 | Operation | MS150026/02E 2013-11