122 – HI T-ECU
Yellow alarm; warning
Cause
Corrective action
Temperature of the electronics
too high.
u
Check engine room ventilation.
141 – AL Power too high
Yellow alarm; warning
Cause
Corrective action
The average power rate over the
last 24 hours of engine operation
has exceeded the set maximum
value.
u
-
180 – AL CAN1 Node Lost
Yellow alarm; warning
Cause
Corrective action
Connection to a node on CAN bus
1 failed.
1. Check devices connected to CAN.
2. Check wiring (termination resistor installed?).
181 – AL CAN2 Node Lost
Yellow alarm; warning
Cause
Corrective action
Connection to a node on CAN bus
2 failed.
1. Check devices connected to CAN.
2. Check wiring (termination resistor installed?).
182 – AL CAN Wrong Parameters
Yellow alarm; warning
Cause
Corrective action
Incorrect parameter values
entered in data record.
u
Contact Service.
183 – AL CAN No PU Data
Yellow alarm; warning
Cause
Corrective action
The selected CAN mode initializes
communication by means of the
PU data module. However, the
required PU data module is not
available or not valid.
1. Check devices connected to CAN.
2. Contact Service.
52 | Troubleshooting | MS150094/02E 2015-05