3.7 After stopping the engine – Putting the engine out of
operation
Preconditions
☑
MTU Preservation and Represervation Specifications (A001070/..) are available.
NOTICE
Engine coolant with inadequate freeze protection. Water remaining in the pressure sensors freezes at
temperatures below 0 °C.
Risk of sensor damage!
• Remove pressure sensors and shake off residual water.
After stopping the engine
Item
Measure
Coolant circuit
Drain engine coolant (→ Page 114) and
Drain charge-air coolant (→ Page 125) if
• freezing temperatures are expected, the engine is to remain out of service
for an extended period, but engine coolant has no antifreeze additive.
• the engine room is not heated.
• the coolant is not kept at a suitable temperature.
• the antifreeze concentration is insufficient for the engine-room tempera-
ture.
• the antifreeze concentration is 50% and the engine room temperature is
below -40 °C.
Engine control system
Switch off (see manufacturer's documentation).
Air intake and exhaust sys-
tem
If the equipment is to remain out of service for more than one week, seal the
engine's air and exhaust sides. Otherwise, components carrying air or ex-
haust gas are at risk of corrosion.
If the equipment is to remain out of service for more than one month, pre-
serve the engine (→ MTU Preservation and Represervation Specifications
A001070/..).
40 | Operation | MS150094/02E 2015-05
TIM-ID: 0000002709 - 010