1.4530.012 – Analog Input High Error
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
F-Series setting is not correct.
u
Check setting.
1.4530.013 – Analog Input Low Error
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
F-Series setting is not correct.
u
Check setting.
1.4530.014 – Input Supply Voltage High Error
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
Supply voltage has reached
maximum limit value.
1. Check supply voltage.
2. Check cabling.
1.4530.015 – Input Supply Voltage Low Error
Yellow alarm. Initiated by F-Series.
Cause
Corrective action
Supply voltage has reached
minimum limit value.
1. Check supply voltage.
2. Check cabling.
1.4530.016 – Electronics Temperature High Error
Red alarm. Initiated by F-Series.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart F-Series.
1.4530.017 – Electronics Temperature Low Error
Red alarm. Initiated by F-Series.
Cause
Corrective action
Hardware not ready for
operation.
u
Restart F-Series.
1.4530.018 – Position Error
Red alarm. Initiated by F-Series.
Cause
Corrective action
Position demand and feedback
do not match
1. Check mechanical system.
2. Restart F-Series.