1.4520.610 – MIC5 ISE Secondary Open Cylinder 1
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 1 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.611 – MIC5 ISE Secondary Open Cylinder 2
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 2 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.612 – MIC5 ISE Secondary Open Cylinder 3
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 3 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.613 – MIC5 ISE Secondary Open Cylinder 4
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 4 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.614 – MIC5 ISE Secondary Open Cylinder 5
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 5 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.615 – MIC5 ISE Secondary Open Cylinder 6
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 6 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
1.4520.616 – MIC5 ISE Secondary Open Cylinder 7
Yellow alarm. Initiated by MIC5.
Cause
Corrective action
Disruption in secondary circuit
of cylinder 7 in firing order.
1. Check ignition line, spark plug connector and spark plug.
2. Check ignition coil.
MS15027/00E 2013-10
| Troubleshooting | 87
TIM-ID: 0000044566 - 001