231 – SD Camshaft Speed
Red alarm. Engine stop.
Associated parameter 1.8004.499
Cause
Corrective action
Camshaft sensor defective,
short circuit or wire break.
u
Check sensor and cabling (B1.1), replace if necessary. Fault is
rectified following engine restart.
232 – SD Charger 1 Speed
Yellow alarm.
Associated parameter 1.3011.128
Cause
Corrective action
Speed sensor of primary
turbocharger defective, short
circuit or wire break.
u
Turbocharger speed sensor is not fitted at present.
233 – SD Charger 2 Speed
Yellow alarm.
Associated parameter 1.3011.129
Cause
Corrective action
Speed sensor of secondary
turbocharger defective, short
circuit or wire break.
u
Turbocharger speed sensor is not fitted at present.
245 – SD ECU Power Supply Voltage
Red alarm.
Associated parameter 2.8006.589
Cause
Corrective action
Internal governor fault.
u
Replace ADEC engine governor.
266 – SD Speed Demand
Red alarm.
Associated parameter 2.8006.586
Cause
Corrective action
Speed setting signal can no
longer be transmitted from
plant.
u
Check signal and cabling between plant and ADEC.
122 | Troubleshooting | MS15027/00E 2013-10