RAW WATER CIRCUIT (open circuit)
Number of cylinders
16
Raw water pump: Inlet pressure, min.
L bar
-0.4
Raw water pump: inlet pressure, max.
L bar
+0.5
Pressure loss in engine-external raw water system, max.
L bar
0.7
LUBE-OIL SYSTEM
Number of cylinders
16
Lube oil operating temperature upstream of engine, from
R °C
75
Lube-oil operating temperature upstream of engine, to
R °C
94
Lube oil operating pressure upstream of engine, from
R bar
6.0
Lube oil operating pressure upstream of engine, to
R bar
7.5
Lube oil operating pressure (low idle) (meas. point: upstream of engine)
R bar
2.5
FUEL SYSTEM
Number of cylinders
16
Fuel pressure at engine inlet connection, min. (when engine is starting)
L bar
-0.3
Fuel pressure at engine inlet connection, min. (when engine is running),
L bar
-0.3
Fuel pressure at engine inlet connection, max. (when engine is starting)
L bar
+0.25
Fuel supply flow, max.
R liters/min
8.6
GENERAL OPERATING DATA
Number of cylinders
16
Firing speed, from
R rpm
100
Firing speed, to
R rpm
120
STARTER (electric)
Number of cylinders
16
Rated starter voltage (standard design)
R V=
24
INCLINATIONS, STANDARD OIL SYSTEM (reference: waterline)
Number of cylinders
16
Longitudinal inclination, continuous max. driving end down (Option: max.
operating inclinations)
L Degrees
(°)
15
Longitudinal inclination, temporary max. driving end down (Option: max. op‐
erating inclinations)
L Degrees
(°)
22.5
Longitudinal inclination, continuous max. driving end up (Option: max. oper‐
ating inclinations)
L Degrees
(°)
0
Longitudinal inclination, temporary max., driving end up (Option: max. oper‐
ating inclinations)
L Degrees
(°)
10
Transverse inclination, continuous max. (Option: max. operating inclina‐
tions)
L Degrees
(°)
22.5
Transverse inclination, temporary max. (Option: max. operating inclinations) L Degrees
(°)
32.5
MS150061/04E 2012-07 | Technical Data | 45
TIM-ID: 0000010887 - 002