Temposonics
®
R-Series EtherNet/IP
TM
Operation Manual
I
2
I
1/
The term qualified technical personnel characterizes persons who:
– are familiar with the safety concepts of automation technology applicable to the
particular project,
– are competent in the field of EMC,
1
/ – have received adequate training for commissioning and service operations
– are familiar with the operation of the device and know the information required for
correct operation provided in the product documentation.
1. Introduction
1.1 Purpose and use of this manual
The content of this technical documentation and of its various annex-
es is intended to provide information on mounting, installation and
commissioning by qualified automation personnel
1
or instructed ser-
vice technicians who are familiar with the project planning and dealing
with Temposonics
®
sensors.
1.2 Used symbols and warnings
Warnings are intended for your personal safety and for avoidance of
damage to the described product or connected devices. In this doc-
umentation, safety information and warnings to avoid dangers that
might affect the life and health of operating or service personnel or
cause material damage are highlighted by the preceding pictogram,
which is defined below.
2. Safety instructions
2.1 Intended use
This product may be used only for the applications provided under
item 1 and item 2 and only in conjunction with the third-party devices
and components recommended or approved by MTS Sensors. As a
prerequisite of proper and safe operation, the product requires correct
transport, storage, mounting and commissioning and must be operat-
ed with utmost care.
1. The sensor systems of all Temposonics
®
series are intended exclu-
sively for measurement tasks encountered in industrial, commercial
and laboratory applications. The sensors are considered as system
accessories and must be connected to suitable evaluation electron-
ics, e.g. a PLC, IPC, indicator or other electronic control unit.
2. The position sensors must be used only in technically safe condition.
To maintain this condition and to ensure safe operation, installation,
connection and service work may be performed only
by qualified technical personnel.
Before starting the operation of Temposonics
®
sensors read this
documentation thoroughly and follow the safety information.
Symbol
Meaning
NOTICE
This symbol is used to point to situations
that may lead to material damage, but not to
personal injury.
Table of contents
1. Introduction ........................................................... 2
1.1 Purpose and use of this manual .......................................... 2
1.2 Used symbols and warnings ............................................... 2
2. Safety instructions................................................... 2
2.1 Intended use ........................................................................ 2
2.2 Forseeable misuse ............................................................... 3
2.3 Installation, commissioning and operation .......................... 3
2.4 Safety instructions for use in explosion-hazardous areas ... 3
2.5 Warranty
............................................................................. 3
2.6 Return ................................................................................. 3
3. Identification ......................................................... 4
3.1 Order structure of R-Series RP ........................................... 4
3.2 Order structure of R-Series RH ........................................... 5
3.3 Order structure of R-Series RD4 ......................................... 6
3.4 Order structure of R-Series RF ............................................ 7
3.5 Nameplate (example) .......................................................... 8
3.6 Approvals ............................................................................ 8
3.7 Scope of delivery ................................................................. 8
4. Product description and commissioning ......................... 8
4.1 Functionality and system design ......................................... 8
4.2 Styles and installation of R-Series RP ................................. 9
4.3 Styles and installation of R-Series RH ............................... 11
4.4 Styles and installation of R-Series RD4 ............................. 13
4.5 Styles and installation of R-Series RF ................................ 19
4.6 Electrical connections ........................................................ 22
4.7 Accessories ...................................................................... 23
5. Operation ............................................................ 24
5.1 Getting started ................................................................... 24
6. IP Address Configuration .......................................... 24
6.1 Set the IP address of the sensor ....................................... 25
7. Integration in RSLogix5000 ....................................... 26
7.1 Install the MTS EtherNet/IP EDS file .................................. 28
7.2 Add sensor to I/O configuration using EDS file ................. 28
7.3 Add sensor to I/O configuration w/o using EDS file ........... 29
7.5 Verify Generic EtherNet Module......................................... 30
7.6 Controller tags configuration data ..................................... 31
8. Maintenance and troubleshooting ............................... 34
8.1 Error conditions, troubleshooting ...................................... 34
8.2 Maintenance ...................................................................... 34
8.3 Repair ................................................................................ 34
8.4 List of spare parts ............................................................. 34
8.5 Transport and storage ....................................................... 34
9. Technical data ....................................................... 35
0. Annex ................................................................. 36
1. Appendix A - Sensor Reset ........................................ 37
2. Appendix B - Port Details .......................................... 38
1
1
1