Temposonics
®
R-Series EtherNet/IP
TM
Operation Manual
I
3
I
2/
see also applicable MTS Sales and supply conditions, e.g. under www.mtssensors.com
Do not reprocess the sensor afterwards.
The sensor might be damaged.
Do not step on the sensor.
The sensor might be damaged.
2.2 Forseeable misuse
2.3 Installation, commissioning and operation
The position sensors must be used only in technically safe condition.
To maintain this condition and to ensure safe operation, installation,
connection and service work may be performed only by qualified tech-
nical personnel.
If danger of injury to persons or of damage to operating equipment
is caused by sensor failure or malfunction, additional safety measures
such as plausibility checks, limit switches, EMERGENCY STOP sys-
tems, protective devices etc. are required. In the event of trouble,
shut down the sensor and protect it against accidental operation.
Safety instructions for commissioning
To maintain the sensor operability, it is mandatory to follow the in-
structions given below.
1. Protect the sensor against mechanical damage during installation
and operation.
2. Do not open or dismantle the sensor.
3. Connect the sensor very carefully and pay attention to the polarity
of connections and power supply.
4. Use only approved power supplies.
5. It is indispensable to ensure that the specified permissible limit
values of the sensor for supply voltage, environmental conditions,
etc. are met.
6. Check the function of the sensor regularly and provide documenta-
tion of the checks.
7. Before system switch-on, ensure that nobody’s safety is jeopar-
dized by starting machines.
2.4 Safety instructions for use in explosion-hazardous areas
The sensor is not suitable for operation in explosion-hazarded areas.
2.5 Warranty
2
MTS Sensors grants a warranty period for the Temposonics
®
posi-
tion sensors and supplied accessories relating to material defects and
faults that occur despite correct use in accordance with the intended
application
2
. The MTS Sensors obligation is limited to repair or re-
placement of any defective part of the unit. No warranty can be taken
for defects that are due to improper use or above average stress of the
product, as well as for wear parts. Under no circumstances will MTS
Sensors accept liability in the event of offense against the warranty
rules, no matter if these have been assured or expected, even in case
of fault or negligence of the company.
MTS Sensors explicitly excludes any further warranties. Neither the
company’s representatives, agents, dealers nor employees are autho-
rized to in- crease or change the scope of warranty.
2.6 Return
For diagnostic purposes, the sensor can be returned to MTS Sensors
or an authorized repair facility. Any shipment cost will be borne by the
sender
2
. For a corresponding form, see chapter 9 (Annex).
Forseeable misuse
Consequence
Wrong sensor connection
The sensor does not work
properly or will be destroyed
Operate the sensor out off the
operating temperature
No signal output
The sensor can be damaged
Power supply is out of the
defined range
Signal output is wrong/
no signal output/
the sensor will be damaged
Position measurement is
influenced by an external
magnetic field
Signal output is wrong
Cables are damaged
Short circuit – the sensor can
be destroyed/sensor does not
respond
Magnet spacers are missing/
are installed in the wrong order
Error in position measurement
Wrong connection
of ground/shield
Signal output is disturbed
The electronics can be damaged
Use of a magnet that is not
certified by MTS Sensors
Error in position measurement