Temposonics
®
E-Series CANopen
Operation Manual
41
8. Technical data
7/
Only sensors with connector outlets are UL/cUL certified
Electrical connection
Connection type
5 pin connector M12 or cable outlet (EH only)
Cable
EHx (530166)
ETx (530157)
Dimension
3 × 2 × 0.14 mm²
3 × 2 × 0.14 mm²
Cable Ø
6.2 mm (0.24 in.)
6.7 mm (0.26 in.)
Material
PUR, silver-grey
FEP, black
Operating temperature
−40…+80 °C (−40…+176 °F)
−100…+180 °C (−148…+356 °F)
Characteristics
Oil resistant, energy chain, halogen free
Operating voltage
+24 VDC (−15 / +20 %); UL Recognition requires an approved power supply with energy
limitation (UL 61010-1), or Class 2 rating according to the National Electrical Code (USA) /
Canadian Electrical Code.
6
Ripple
≤ 0.28 V
PP
Current consumption
40…60 mA depending on stroke length
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −30 VDC
Overvoltage protection
Up to 36 VDC