Temposonics
®
E-Series CANopen
Operation Manual
16
Multi position measurement
The minimum distance between the magnets is 75 mm (3 in.).
Temposonics
®
E-Series EP with U-magnet
Temposonics
®
E-Series EP with block magnet
75
(3)
75
(3)
Temposonics
®
E-Series EP with magnet slider S & V
Temposonics
®
E-Series EL with magnet slider S & V
75
(3)
75
(3)
Temposonics
®
E-Series EL with block magnet
Temposonics
®
E-Series EH with ring or U-magnet
75
(3)
75
(3)
Fig. 15: Minimum distance for multi position measurement
Controlling design dimensions are in millimeters and measurements in ( ) are in inches