OPERATING AND MAINTENANCE MANUAL
Chapter 2 - Safety
TAEevo Tech MINI 02÷10
6
The data in this manual are not binding and they can be modified by the manufacturer without notice.
Reproduction of this manual is strictly prohibited
ENGLISH
EN
2 . 3
L i f t i n g a n d t r a n s p o r t p r e c a u t i o n s
Avoid injury by using a hoist to lift heavy loads.
Check all chains, hooks, shackles and slings are in good condition and are of the correct capacity.
They must be tested and approved according to local safety regulations.
Cables, chains or ropes must never be attached directly to lifting eyes.
Always use an appropriate shackle or hook properly positioned. Arrange lifting cables so that there are no sharp bends.
Use a spreader bar to avoid lateral loading of hooks and eyebolts.
When a load is lifted from the ground keep well clear of the area beneath the load and the immediately surrounding area.
Keep lifting acceleration and speed well within safety limits and never leave a suspended load attached to a hoist any longer
than strictly necessary.
The weight values shown in the table below were obtained with the unit empty and in the basic configuration.
The manufacturer does not supply load spreaders, lifting straps or hooks with the unit.
NOTE
Weight values are guideline, with the water circuit empty. The values may vary in relation to the configuration of the unit.
NOTE
The unit is complete with eyebolts for lifting, which can be used once the packaging has been removed.
2 . 4
P r e c a u t i o n s t o b e a d o p t e d d u r i n g i n s t a l l a t i o n
The connections to be prearranged concern the process water circuit. For connection to the mains electrical supply consult
the technical documentation attached to the unit..
2 . 5
P r e c a u t i o n s t o b e a d o p t e d d u r i n g o p e r a t i o n
The unit must be operated by competent personnel under the guidance of a qualified supervisor.
All water pipelines must be painted or clearly marked in compliance with local safety prescriptions in force in the place of
installation.
ATTENTION
Do not remove or tamper with safety devices, protections, or the insulating materials installed in the unit and in the
auxiliary equipment.
All electrical connections must comply with local codes.
The unit and its auxiliary equipment must be connected to earth and protected against short circuits and overloads.
Model TAEevo Tech MINI
02
03
05
08
10
Weight (kg)
60
62
63
74
78
Summary of Contents for TAEevo Tech MINI