background image

User’s Manual

                                                                                       

SOL10P12 Series 

 

Operation

 

Guide

 

 

1.

 

Connect the battery to the BAT terminal. Make sure the polarities are 
correctly connected. Sequentially connect the solar panel to SOL terminal 
and connect POE source to PoE input (lower) jack. (If solar panel or PoE 
source is installed before the battery, and if the polarities of the battery be 
reversed, then the fuse will be burnt.) 
 

2.

 

Make sure the battery is properly connected to the unit. If no battery is 
connected, then the voltage at BAT terminal will be approx 13.8V 

 

3.

 

The solar panel cannot be used stand alone without battery connected. 

 

4.

 

When a solar panel and PoE input are connected to the charger, if the 
voltage of solar panel is higher than 15V, then solar panel is always the 
main power source of the charger.  

 

5.

 

When charge from solar panel, as the battery full and turn to floating 
stage, the CHA light will start flash.  

 

6.

 

When charge from PoE, as the battery full, the CHA light will be turn off, if 
the CHA is always flash, that means the input wattage lower than the 
required minimum wattage. If only charge battery, the minimum input 
wattage is 45W. 

 

7.

 

When battery connect to BAT terminal and with valid voltage, then the 

LOA indicator will always light on even no load connected.

 

 

Summary of Contents for SOL10P12 Series

Page 1: ...Mstronic Co Ltd SOL10P12 Series Solar PoE Battery Charger USER S MANUAL...

Page 2: ...L10P12 56A1N SOL10P12 56B1N DIN Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Pr...

Page 3: ...polarity reverse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57...

Page 4: ...3 The solar panel cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 15V then solar pane...

Page 5: ...SOL10P12 Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be prope...

Page 6: ...erminal Output 2 at front upper RJ45 SOL10P12 24BNN 12V 10A as Bat Volt 24V 1 25A 45 78 regulated SOL10P12 48ANN 12V 10A as Bat Volt 48V 0 625A 12 36 regulated SOL10P12 48ANR 12V 10A as Bat Volt 48V 0...

Page 7: ...function will be disable if there is PoE power sources connected when the battery polarities reversed the fuse will be burnt 5 2 Battery Over Discharge Protection Cuts off the load when the battery vo...

Page 8: ...The fuse will be burnt when battery output current over 10A 5 8 Load Output Voltage Limit The output voltage of the rear terminal is the same as battery 5 91 POE Charge Voltage Float 13 4V 0 2V Equal...

Page 9: ...3 Vdc BI_DB power Data Pair B Vdc BI_DB power Data Pair B 4 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 5 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 6 Vdc BI_DB power Data Pai...

Reviews: