3.

 

Battery Charge Current: 

A. Solar Panel: depends on the solar panel, 10A max, 
B. POE: fixed current, 2.0A max 

 

4.

 

Battery Types: 12V AGM Battery 

 

5.

 

 Protection: 

5.1

 

Battery Polarity Reverse Protection: 
If only battery connected to terminal, when the battery polarities 
were reversed, the model will stop output and REV indicator light 
on.  
When the battery be removed and re-connected to terminal, the 
function will be disable, if there is PoE power sources connected, 
when the battery polarities reversed, the fuse will be burnt. 

 

5.2

 

Battery Over Discharge Protection:  
Cuts off the load when the battery voltage is lower than 11V + 0.3V, 
and auto recover when the battery voltage returns to 12 V + 0.3V 

 

5.3

 

Battery Over Charge Protection:  
Fuse control, over 10A, the fuse will be burnt. 

 

5.4

 

Solar Panel Polarity Reverse Protection:   
When solar panel polarities be reversed, the charger stop output, it 
won’t damage the charger or end device 

 

5.5

 

Solar Panel Over Charge Protection:   
When charge current over 10A, the fuse will be burnt. 

Summary of Contents for SOL10P12 Series

Page 1: ...Mstronic Co Ltd SOL10P12 Series Solar PoE Battery Charger USER S MANUAL...

Page 2: ...L10P12 56A1N SOL10P12 56B1N DIN Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Pr...

Page 3: ...polarity reverse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57...

Page 4: ...3 The solar panel cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 15V then solar pane...

Page 5: ...SOL10P12 Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be prope...

Page 6: ...erminal Output 2 at front upper RJ45 SOL10P12 24BNN 12V 10A as Bat Volt 24V 1 25A 45 78 regulated SOL10P12 48ANN 12V 10A as Bat Volt 48V 0 625A 12 36 regulated SOL10P12 48ANR 12V 10A as Bat Volt 48V 0...

Page 7: ...function will be disable if there is PoE power sources connected when the battery polarities reversed the fuse will be burnt 5 2 Battery Over Discharge Protection Cuts off the load when the battery vo...

Page 8: ...The fuse will be burnt when battery output current over 10A 5 8 Load Output Voltage Limit The output voltage of the rear terminal is the same as battery 5 91 POE Charge Voltage Float 13 4V 0 2V Equal...

Page 9: ...3 Vdc BI_DB power Data Pair B Vdc BI_DB power Data Pair B 4 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 5 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 6 Vdc BI_DB power Data Pai...

Reviews: