background image

User’s Manual

                                                                                       

SOL10P12 Series 

 

Features: 

 

 

Dual Input, from solar panel and/or PoE (Solar First) to charge 12V 
battery,  and  another  two  outputs:  PoE  output  on  front  and/or 
terminal block on rear 

 

Built-in  DC/DC  converter,  with  various  passive  PoE  output,  24V, 
48V, 56V available. (12V, 18V build to order) 

 

Active PoE Output support 802.3at handshake  
(SOL10P12-56A1N, SOL10P12-56B1N) 

 

DIN Rail Mountable 

 

Support Gigabit Ethernet  
 

Applications: 

 

Remote Power Systems; Surveillance, Sensors 

 

Wireless Station; AP/Client/Repeaters 

 

UPS Systems; Lighting, Fences, Gates 
 

Protection: 

 

 

Battery Polarity Reverse Protection 

 

Battery Over Charge Protection 

 

Battery Over Discharge Protection 

 

Solar Panel Polarity Reverse Protection 

 

Solar Panel Over Charge Protection  

 

Output Short Circuit Protection 

 

Output Over Voltage Protection 

 

POE Output Short Circuit Protection 

 

Externally fused with a standard replaceable fuse

 

Summary of Contents for SOL10P12 Series

Page 1: ...Mstronic Co Ltd SOL10P12 Series Solar PoE Battery Charger USER S MANUAL...

Page 2: ...L10P12 56A1N SOL10P12 56B1N DIN Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Pr...

Page 3: ...polarity reverse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57...

Page 4: ...3 The solar panel cannot be used stand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 15V then solar pane...

Page 5: ...SOL10P12 Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be prope...

Page 6: ...erminal Output 2 at front upper RJ45 SOL10P12 24BNN 12V 10A as Bat Volt 24V 1 25A 45 78 regulated SOL10P12 48ANN 12V 10A as Bat Volt 48V 0 625A 12 36 regulated SOL10P12 48ANR 12V 10A as Bat Volt 48V 0...

Page 7: ...function will be disable if there is PoE power sources connected when the battery polarities reversed the fuse will be burnt 5 2 Battery Over Discharge Protection Cuts off the load when the battery vo...

Page 8: ...The fuse will be burnt when battery output current over 10A 5 8 Load Output Voltage Limit The output voltage of the rear terminal is the same as battery 5 91 POE Charge Voltage Float 13 4V 0 2V Equal...

Page 9: ...3 Vdc BI_DB power Data Pair B Vdc BI_DB power Data Pair B 4 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 5 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 6 Vdc BI_DB power Data Pai...