67
RAID Configuration
Rebuilding RAID Array
A RAID 1, RAID 5 or RAID 10 volume is reported as
Degraded
when one of its hard
drive members fails or is temporarily disconnected, and data mirroring is lost. As a
result, the system can only utilize the remaining functional hard drive member. To
re-establish data mirroring and restore data redundancy, refer to the procedure below
that corresponds to the current situation.
1.
Power off.
2.
Replace the failed hard drive with a new one that is of equal or greater capacity.
3.
Reboot the system and go to
BIOS > SETTING > Advanced > Intel(R) Rapid Storage
Technology
.
4.
Select the
Degraded
RAID volume from the
Intel(R) Rapid Storage Technology
screen to enter the
RAID VOLUME INFO
screen.
5.
Select the
Rebuild
item and press
Enter
key to rebuild the new hard drive.
Summary of Contents for MPG Z390 GAMING PLUS
Page 2: ...2 Quick Start https youtu be 4ce91YC3Oww Installing a Processor 1 2 3 6 4 5 7 8 9 ...
Page 5: ...5 Quick Start BAT1 Installing the Motherboard 1 2 ...
Page 6: ...6 Quick Start Installing SATA Drives http youtu be RZsMpqxythc 1 2 3 4 5 ...
Page 7: ...7 Quick Start 1 Installing a Graphics Card http youtu be mG0GZpr9w_A 2 3 4 5 6 ...
Page 8: ...8 Quick Start Connecting Peripheral Devices ...
Page 9: ...9 Quick Start Connecting the Power Connectors http youtu be gkDYyR_83I4 ATX_PWR1 CPU_PWR1 ...