42
MSI-7300 Operator’s Manual
6.4 802.15.4 RF Network Setup
When equipped with the 802.15.4 option, the
Dyna-Link 2
can connect with an
MSI-8000
Remote Display or an 802.15.4 modem. The unit uses three numbers to
connect to an 802.15.4 piconet:
1. ScaleCore ID – uniquely identifies each ScaleCore device in a piconet. It has a
range of 0-254 and must not be duplicated within the same RF channel. For the
MSI-8000
as network coordinator, MSI recommends a number for the
Dyna-
Link 2
from 0-3 if multiple units will be connected to the
MSI-8000
. If a single
Dyna-Link 2
is all that’s needed than any number up to 254 is acceptable.
2. RF Channel – establishes the base network, all interconnected devices must
match. This number must be in the range of 12-23.
3. Network ID – this is a 64-bit number that all interconnected devices must match.
The
Dyna-Link 2
limits this number to a max of 5 digits for a range of 0 - 99999.
Do not use a small number here to help avoid other 802.15.4 networks that
default to a network ID of 0.
4. RF Strength – Transmission strength can be set from 0 to 4, default is 1. The
settings effect the transmission range with zero is lowest power level and four is
the highest. Power 4 will use the battery life quicker, so use the lowest number
possible for reliable transmission. If maximum range is needed set the strength
to four.
3ULQW
U)
Serial Out Setup
rF Modem
2Q2II
6&LG
&KQO
QHWLG
RF On/Off
ScaleCore ID
RF Channel
Network ID
2Q
2II
RF On
RF Off
RF SETUP
Range 0-254
Range 12-23
Range 1 to 999999
0
ZERO
F1
F2
Press Simultaneously
6WU(Q
Transmission Strength
Range 0 to 4
Note
For all devices that interconnect, the RF channel and network ID must
match. The ScaleCore ID must be unique. The Dyna-Link 2 or other
MSI RF equipment that is a weight data source should be set to a
ScaleCore ID of 0, then if other slave devices are added, they can be
added in sequence.
Figure 6-6 RF Menu