User Key Functions (F1and F2)
17
3.9
HI-RES
Set a function key (
Fx
) to
Hi-Res
, see Section 4.0.
Press the
Fx
key programmed to display the high resolution mode (see Table 1-2 on
page 8). The display will stay in high resolution mode until the selected
Fx
key is
pressed again, or power is cycled. While in the hi-res mode the appropriate
Fx
LED
will blink continuously at a slow rate.
Hi-res mode does not increase the accuracy, but allows for smaller weight increments
to be displayed.
Use Tare or the
ZERO
key to zero out any initial error. Hi-res mode will make the
Dyna-Link 2
more sensitive to motion and movement resulting in a less stable display.
When hi-res is on, the filter is automatically set to the Hi-1 setting (if Hi-2 is already
set, then the filter is not changed). This will have a small effect on settling time. When
hi-res is turned off, the filter setting resets to the previous filter setting.
3.10 PRINT
Set a function key (
Fx
) to
, see Section 4.0.
Pressing the
Fx
key outputs a configured text string to the RS-232 port on the base of
the unit.
If an F-Key is programmed as print and the print setup is configured as continuous,
then the
Fx
key is used for start print/stop print. See Section 6.2 for more details on
data output.
The print function is always available on the optional RF remote display, so it is not
necessary to program an F-Key to “print” if you intend to trigger print outputs from
the remote.
However, if you program F1 or F2 to “print” then pushing F1 or F2 on the Dyna-Link
will cause the comm port on the remote to output the selected data string.
If the RF remote display option is installed, the Dyna-Link cannot use its built in
comm port except for hard-wire connections to the RF remote display or firmware
updates.