Communication Setup
41
6.3 Comm Port Hardware
The
Dyna-Link 2
RS-232 comm port is used for software updates, connecting to a
remote display, and for connecting to any RS-232 device.
Table 6-2. Comm Port Hardware
Connector
M12 industrial IP67 rated. An adapter cable (P/N 503363) is
required to connect the
Dyna-Link 2
to a computer. This
adapter cable converts the
Dyna-Link 2
connector to a
standard D9 serial connector.
Data Configuration
The data output is fixed at 8-1-N.
Baud Rate
Programmable for 300 to 230.4k baud in eight steps. The
bootloader for updating software is always 38.4k baud.
Handshaking
No hardware handshaking is supported XON/XOFF software
handshaking is always on.
It may be necessary to disconnect the shield drain wire at the D-9
connector frame to prevent ground loops. Ground loops can cause
unstable readings. In extreme cases it may be necessary to use an
opto-isolated RS-232 interface.
Note
Figure 6-4 Serial Cable Schematic, DCE Configuration for
Connecting to a Computer
Figure 6-5 Serial Cable Schematic,
DTE Configuration for Connecting Directly to a DCE Printer