Dyna-Link Setup
21
4.4 Setpoints
The
Dyna-Link 2
supports two setpoints. Common uses of set points are for warnings
or process control. The
MSI-7300 Dyna-Link 2
comes standard with two high
brightness red LED outputs for a triggered set point. The
MSI-7300 Dyna-Link 2
has
an audible output option that is triggered by setpoint 1. Contact MSI for other setpoint
output options.
1) With the 7300 on, press the
F2
and
POWER
keys
simultaneously.
2) Scroll through the setup menu
choices by pressing the
F2
key.
Stop when the LED displays
StPt1
or
StPt2
.
3) When the desired setpoint is
displayed, press
F1
. The display
blinks
OFF
, or if previously
programmed, the last set mode.
4) Select the setpoint mode by
scrolling through the choices with
the
F2
key.
GrEAt
(greater than)
indicates the setpoint will trigger
when the tension exceeds the
value.
LESS
(less than) will
trigger the setpoint when the
tension is less than the value.
This example scrolled through all available
choices for illustration purposes only.
5) When the desired setpoint
mode is displayed, press
F1
.
6) Next select the type of tension
or weight value the set point is
assigned to. Use the
F2
key to
scroll through the choices.
This example scrolled through all
available choices for illustration
purposes only.In this example, we’ll
enter Gross as the tension mode
because we are going to use the set
point as a safety warning.
7) When the desired weight mode
is shown, push
F1
. Next the
current setpoint value is
displayed.
If there was a previous
value, it is displayed. If no value has
been entered, a zero will appear. To
keep the displayed value, press
ZERO
.
VWSW
UHDW
2II
blinking
/(66
UHDW
Current Value (if any)
Set Point responds to Gross
tension, regardless of the
display mode.
Set Point responds to the
tension on the display, Net
or Gross Weight.
Set Point responds to the
Totaled Weight.
Set Point responds to
the Total Count (number
of samples).
Press Simultaneously
POWER
F2
F2
SCROLL
ENTER/SELECT
F1
ENTER/SELECT
F1
SCROLL
F2
SCROLL
F2
SCROLL
F2
SCROLL
F2
SCROLL
F2
SCROLL
F2
F2
SCROLL
Set Point responds to Gross
tension, regardless of the
display mode.
URV6
blinking
QHW U
blinking
WRWDO
blinking
WFQW
blinking
URV6
blinking
0
ZERO
F1
Figure 4-4 Setpoint Setup