MrHeater MHU200NG Operating Instructions And Owner'S Manual Download Page 2

Large Unit Heater

2

Operating Instructions and Owner’s Manual

MHU200NG

MHU250NG

MHU300NG

MHU400NG

V/A/H/Phase

120v / 6.3A / 60hZ / 1Ø

120v / 6.3A / 60hZ / 1Ø

120v / 10A / 60hZ / 1Ø

120v / 10A / 60hZ / 1Ø

BTU Input

200,000 BTU

250,000 BTU

300,000 BTU

400,000 BTU

BTU Output

160,000 BTU

200,000 BTU

240,000 BTU

320,000 BTU

Efficiency %

80%

80%

80%

80%

LANGUAGES

ENGLISH  ..........................................................1 - 28
SPANISH  ....................................................... 29 - 56
FRENCH  ........................................................ 57 - 84

CONTENTS

SAFETY.............................................................................2
INTRODUCTION...............................................................5
INSTALLATION.............................................................. ...6
START-UP........................................................................16
MAINTENANCE..............................................................20
FUEL CONVERSION INSTRUCTIONS................................22
TROUBLESHOOTING GUIDE............................................24
PARTS LIST .................................................................  26
WARRANTY ................................................................  28

GENERAL INFORMATION

RETAIN THIS MANUAL FOR FUTURE REFERENCE.
FOR QUESTIONS, PROBLEMS, MISSING PARTS BEFORE 
RETURNING TO RETAILER PLEASE CALL WITH MODEL NUMBER 
AND SERIAL NUMBER OF HEATER:
1-800-251-0001
MONDAY-FRIDAY 8-5 EASTERN TIME
OR E-MAIL USING THE MR. HEATER WEBSITE:

WWW.MRHEATER.COM

In order to provide the best service possible Mr. Heater

 

 

is 

now giving you more ways to get in touch with us. Find 
informational videos at:

        

 Facebook: www.facebook.com/mrheaterproducts/

        

 Twitter: https://twitter.com/MrHeater

 WARNING:

  YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, 

SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU 
OPERATE THIS HEATER.

 WARNING:

 FIRE OR EXPLOSION HAZARD

  Failure to follow safety warnings exactly could result in 

serious injury, death or property damage. Be sure to read 
and understand the installation, operation, and service in 
this manual. Improper installation, adjustment, alteration, 
service or maintenance can cause serious injury, death or 
property damage.

 WARNING:

 

 

FIRE, BURN, INHALATION, AND EXPLOSION 
HAZARD. Keep solid combustibles, such as 
building materials, paper, or cardboard, 
a safe distance away from the heater. As 
recommended by the instructions never 
use the heater in spaces which do or may 
contain volatile or airborne combustibles, 
or products such as gasoline, solvents, 
paint thinner, dust particles or unknown 
chemicals.

 WARNING:

THIS PRODUCT CAN EXPOSE 

YOU TO CHEMICALS INCLUDING LEAD AND LEAD 
COMPOUNDS, WHICH ARE KNOWN TO THE STATE 
OF CALIFORNIA TO CAUSE CANCER AND BIRTH 
DEFECTS OR OTHER REPRODUCTIVE HARM. FOR MORE 
INFORMATION VISIT WWW.P65WARNINGS.CA.GOV

 WARNING: 

Fuels used in liquefied propane 

gas appliances, and the products of combustion of such 
fuel, can expose you to chemicals including benzene, which 
is known to the state of California to cause cancer and 
cause birth defects or other reproductive harm, for more 
information go to  www.P65Warnings.ca.gov

SAFETY

Summary of Contents for MHU200NG

Page 1: ...o this manual For assistance or additional information consult a qualified installer service agency or the gas supplier WHAT TO DO IF YOU SMELL GAS DO NOT try to light appliance DO NOT touch any elect...

Page 2: ...E INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Be sure to read and und...

Page 3: ...perly Set ________________________________ Furnace BTU input _____________________________________ Level ___________________________________________________ Line Pressure _____________________________...

Page 4: ...al Standard Institute Inc 11 West 42nd Street New York NY 10036 These units are CSA International design certified These unit heaters are certified for installation to combustible material as listed i...

Page 5: ...nual is to provide information regarding safety design guidelines installation operation and maintenance of the this gas fired unit heater You must read and understand the instructions and all safety...

Page 6: ...tion of these units must comply with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition and other applicable local building codes In Canada the installation of these units must comply with...

Page 7: ...ontal pitch as directed in these instructions and the latest edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 or CSA B149 1 Installation Code Determine that there is not blockage restriction...

Page 8: ...h a diameter 4 inches greater than the vent pipe diameter must be used If there is 6 feet or more of vent pipe prior to passing through the combustible wall or floor then the metal thimble need only b...

Page 9: ...than any part of a building within a horizontal distance of 10 3 05m unless otherwise specified by the American National Fuel Gas Code ANSI Z223 1 or Canada CAN CGA B149 Installation Code The vent mu...

Page 10: ...ombustion which can result in the production of excessive carbon monoxide Follow these guidelines and all applicable codes for all models prior to installing the combustion air duct work WARNING Suffi...

Page 11: ...drip leg should be installed in the vertical pipe run to the unit In some localities codes may require that a manual main shutoff valve and union furnished by installer be installed external to the un...

Page 12: ...putting into service For leak testing on pressures below 20 inches W C Before leak testing close the field installed manual shut off valve shown on Figure 9 on the supply line to isolate the gas valve...

Page 13: ...ssure Input Rating W C kPa BTU Hr W W C kPa BTU Hr W MHU200NG 7 23 1 8 200 000 58 614 6 66 1 66 192 000 56 269 MHU250NG 7 23 1 8 250 000 73 268 6 66 1 66 240 000 70 337 MHU300NG 3 81 0 95 300 000 87 9...

Page 14: ...the side access control compartment of the unit The low voltage thermostat and accessory control devices can be wired to the terminals in the side access control compartment Refer to the wiring diagra...

Page 15: ...Large Unit Heater 15 Operating Instructions and Owner s Manual Main Components FIGURE 10 Line Voltage Thermostat Wiring Connector on Heater S1 S4 M1 VG MC FS S2 S3 S2 CB SE T1 RFC CFC...

Page 16: ...Large Unit Heater 16 Operating Instructions and Owner s Manual Internal Wiring Diagram FIGURE 11...

Page 17: ...field supplied power wires so that they do not come in contact with the flue wrapper or venter housing These hot surfaces may damage the wire s insulation resulting in damage to the unit THERMOSTAT LO...

Page 18: ...puts set it to the maximum rating 7 Observe the pressure rating on the pressure gauge Verify maximum inlet gas supply pressure 8 Turn off all other gas appliances on the same supply line 9 Observe the...

Page 19: ...manifold pressure hose connector using a soap solution or equivalent method as described in ANSI Z223 1 NFPA 54 Prior to Leaving Job Site Prior to leaving the job site verify that Service access door...

Page 20: ...hts burner DO NOT attempt to light the burners manually 5 There is a main shut off valve upstream of the unit Open it See Figure 9 on Page 11 6 Wait five minutes to clear out any gas If you then smell...

Page 21: ...upply Follow lighting instructions to light unit Check burner flame FLUE PASSAGEWAY AND FLUE BOX The flue passages and flue box should be inspected and cleaned prior to each heating season The sequenc...

Page 22: ...old Screws FUEL CONVERSION INSTRUCTIONS FIGURE 15 Rotation of the Valve Manifold Assembly ROTATE valve manifold assembly The heater is standard manufactured for operation with natural gas In case of u...

Page 23: ...NOT FOLLOWED EXACTLY A FIRE EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE THE QUALIFIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES RES...

Page 24: ...space tightly sealed building 1 Remove obstruction or correct vent lengths 2 Replace wiring or hose connections 3 Replace pressure switch The control board does not send spark to the electrode 1 The e...

Page 25: ...ontrol board does not send 120 VAC to the air movement fan after approx 30 seconds after ignition and if contact relay fan control is open and there isn t 24VAC on relay fan control 3 The control boar...

Page 26: ...er listed on the unit rating plate Mr Heater Large Unit Heater Model MHU200NG MHU250NG MHU300NG MHU400NG Liquid Propane to Natural Gas Conversion Kit MHU200NG F260165 MHU250NG F260166 MHU300NG F260167...

Page 27: ...60291 60291 60291 60291 20 BLOWER DRIVE RELAY 60292 60292 60292 60292 21 PRESSURE SWITCH 60293 60294 60294 60294 22 DETECTION ELECTRODE 60295 60295 60295 60295 23 MANUAL RESET SAFETY THERMOSTAT 140 C...

Page 28: ...001 Address any Warranty Claims to the Service Department Mr Heater Inc 4560 W 160TH ST CLEVELAND OHIO 44135 Include your name address and telephone number and include de tails concerning the claim Al...

Reviews: