5 Mounting
Maschinenfabrik Reinhausen GmbH 2020
59
4983703/01 EN
VACUTAP
®
VV-Ex
2.
NOTICE!
Tensile forces can lead to damage and malfunctions on the on-
load tap-changer. Using spacers, insert on-load tap-changer vertically into
supporting structure (maximum 1° deviation from the vertical) so that the
on-load tap-changer reaches its final installation height and only has to be
raised a maximum of 5 to 20 mm after fitting the bell-type tank.
Figure 34: Supporting structure
3. Temporarily fasten on-load tap-changer to supporting structure. The sup-
porting flange has through holes for this purpose.
Figure 35: Temporary fastening