Installation, Operating & Maintenance Manual
4
6. Install steambath generator on a solid and level surface,
and mechanically secure generator in place.
7. Provide access to the steambath generator for servicing.
See page 4 for Dimensional & Clearance Specifications
8.
IMPORTANT:
Steam line, safety valve and drain valve
and plumbing, and steamheads become hot during opera-
tion and remain hot after shutdown for a period of time.
Provide appropriate protection, including insulating plumb-
ing lines. Avoid plumbing runs and steam head locations
that can come in contact with service personnel and
bathers. See page 6.
9. Each steamhead must be located away from
the bather seating areas and traffic patterns as required to
prevent incidental contact with the steamhead or direct steam
emission.
IMPORTANT: A LOCKED UTILITY ROOM THAT ONLY
PERMITS ACCESS TO THE STEAM GENERATOR AND ITS
CONTROLS BY AUTHORIZED PERSONNEL AND IS NOT
ACCESSIBLE TO THE GENERAL PUBLIC IS STRONGLY
RECOMMENDED.
LOCATING THE STEAM GENERATOR UNIT
(1-4):
1. Mr.Steam
®
CU commercial steambath generators are
designed to NEMA Type 1 requirements and are intended
for
indoor use only. They are to be located indoors in a dry, clean
location and are not to be subjected to moisture, conden-
sate, hose wash down or the like.
2. Do NOT install steambath generator outdoors or wherever
environmental conditions may effect the safety and/or per-
formance of the generator.
3. Do NOT install steambath generator in locations such as
unheated attics or basements, or where water could freeze.
4. Do NOT install steambath generator near flammable or
corrosive materials, or chemicals such as gasoline, paint thin-
ners, or the like. Installation in areas having high concentra-
tions of chlorine (such as pool equipment room) must be
avoided.
5.
IMPORTANT:
Select a location for steam generator in
accordance with items 1-4 above and within 25 feet of
the steam room. Reference “Dimensional & Clearance
Specifications” information on pg. 4. See page 5 for guid-
ance if generator is more than 25 feet from steam room.
U T I L I T Y R O O M
Figure 1
3
⁄
4
" Steam
Solenoid
3
⁄
4
" Steamhead
with Acrylic Shield
Steam
Generator
Fully
Insulated
Steam Pipe
Digital 1 Sensor
1" Steam
Outlet
S T E A M R O O M
e
NOTE: FOR ILLUSTRATIVE PURPOSES ONLY.
Optional equipment shown.Consult with qualified designer,
architect or contractor for steam room construction details, including location of steam head(s) and sensors.
FOR ILLUSTRATIVE PURPOSES ONLY
MR. STEAM INSTALLATION
WARNING
!
CAUTION
!