Steam Generator
Steam Vent
mr
.
steam
®
C U S E R I E S
Installation, Operating & Maintenance Manual
18
30 MINUTE ROOM TIMER
The 30 minute timer provides guests in the steam room an accurate and
easy way to safely time their steam sessions. It is available as a Digital
(CU-99216DIG) or Mechanical (CU-99216B) timer.
1. This timer may only be fitted by a qualified electrician.
Shock hazard!
This timer uses the specific supply voltage.
Fit the timer appropriately before connecting it to the main supply. Never
touch the live contacts or components at the open back of the timer.
2. Protection against touch contact must be ensured by a proper mounting.
When fitting the timer, make sure that during normal operation it is
impossible for the end user of the steam generator it was fitted in to
remove the timer by pulling it to the front and exposing the live parts.
3. Avoid any contact of the timer with water.
The 30 Minute Timers shall not be installed inside the steamroom.
4. IMPORTANT:
A steam vent (PN 104072) must be installed in the steam line
between the steam generator and the steam solenoid valve when using a 30
minute timer as shown.
NOTE:
See the Operating Manual for the Digital Timer (PUR 100383) for complete
installation instructions.
NOTE:
All drawings are for illustrative purposes only.
Steam Vents
CU AUTOFLUSH
GRN
WHT
BLK
BRN
Blowdown
Control Panel
Terminal Block
in Steam Generator
Panel Interior
Remove Jumper
NOTE: If the steam generator came with a factory installed
Automatic Blowdown System see page 22 on how to program
the timer.
Hazard of Electric Shock. Disconnect all power supplies
before making wiring connections.
NOTE: Reference applicable wiring diagram.
1. Remove blank cover and mount the Automatic Blowdown Control Panel on the front
of the generator cabinet with screws and nuts provided.
2. Remove the jumper between Brown & Black from the terminal block above the panel.
3. Connect the wires to the terminal block. The terminals are coded with the wire insu-
lation color: Brown-Black-White-Green.
4. Plumb the motorized valve assembly to the generator drain valve.
5. Install the valve cable in the knockout below the Automatic Blowdown Control Panel.
6. Connect the wires to the terminal block at the bottom of the panel. The terminals are
coded with the wire insulation color. CU81600: White-Blue-Red-Green
7. Program the timer and set the clock (See page 24)