UNI MP100 User’s Guide
23
7.8
Instrument Specifications
Size
3.46 x 2.44 x 1.3 in
(88 x 62 x 33 mm)
Weight
4.4 oz (125 g)
Sensors
Electrochemical
Response time
(t90)
15 seconds (CO/H
2
S/O
2
)
Others vary, see individual sensor specification sheet
Battery
Replaceable AA size Lithium battery, 3 years typical operation
Temperature
-4
°F
to 122
°F
(-20
°C
to 50
°C
)
Humidity
5 to 95% relative humidity
(non-condensing)
Alarm Type
• High, Low, STEL & TWA alarms adjustable
• Over range alarm
• Low battery alarm
Alarm Signal
• 95 dB @ 30 cm
• Bright red LEDs
• Built in vibrator
Calibration
2-point calibration, zero and span, power on zero (user-selectable)
Event Log
Up to 50 alarm events
IP Rating
IP-67
EMI/RFI
EMC directive: 2014/30/EU
Safety
Certifications
Class I, Div 1, Group ABCD
Class II, Div 1, Group EFG
Class III, Div 1
T4, -
20°C ≤ T
amb
≤ +50°C
IECEx
Ex ia IIC T4 Ga
ATEX
II 1G
Ex ia IIC T4 Ga
Sensor Life
CO & H
2
S expected operating life 5 years or longer, others 1 to 2 years as per
warranty
Warranty
2 years on O
2
, CO, H
2
S, SO
2
, HCN, NO, NO
2
, and PH
3
units including sensor;
1 year on others