Appendix H
80
Clean working practises
•
Don’t eat, drink or smoke around critical systems/processes.
•
Don’t leave tools, objects, clothing or other materials etc. on surfaces or tanks of
critical systems.
•
Don’t use open tanks on critical systems.
•
Don’t take samples or perform on-line analysis from the top of a reservoir/tank.
•
Don’t design/use tanks which contain crevices (internal corners etc).
•
Don’t assume that if a sample looks clean, that it is. You wont be able to see the
contaminants.
•
Don’t perform off-line analysis in an “un-controlled” environment. E.g. workshop.
•
Don’t rely on a single test for a capable representation of your system.
•
Don’t start using your system/process until it has gone through a commissioning
period whereby contamination levels are relatively stable.
•
Don’t mix fluids into the same system. They can emulsify and eliminate any chance
of a reliable particle count.
•
Don’t use unsuitable containers to take a fluid sample.