4. Technical specification
4.1 Performance
Indicator
Visiwink pressure indicator (only for BS500 version)
Pressure Output
Standard Version 2.5 bar
High Pressure Version 4.5 bar (only for BS500 version)
Vacuum Output (gauge)
18 inHg
4.2 Electrical Interface
Supply Voltage
12V DC
Supply Current
BS110
BS500
2.5 bar version: 2.0A maximum current
2.5 bar version: 5.0A maximum current
4.5 bar version: 8.5A maximum current
4.3 Physical Attributes
Dimensions
BS110
BS500
212 mm (H) x 130 mm (W) x 163 mm (D)
340 mm (H) x 264 mm (W) x 350 mm (D)
Weight
BS110
BS500
1.8 kg - for packed weight see section 2.1
7 kg - for packed weight see section 2.1
Connections
M16x2 hydraulic connection
Hoses
600 mm M16x2 hydraulic pressure hose
Seal Material
M/N Version
Viton
®
(contact MP Filtri for any fluids that are incompatible with Viton
®
seals
S Version - Perflouroelastomer (only for BS500 version)
E Version - EPDM (only for BS500 version)
4.4 Fluid Characteristics
Fluid compatibility
V version - mineral oils, synthetic fluids and diesels
E version – Aerospace phosphate esters, Skydrols
®
S version – Aerospace phosphate esters, Skydrols
®
and V version fluids.
Viscosity
400 cSt
Working temperature
0 °C to +40 °C
4.5 Environment
Ambient working temperature
-10 °C to 80 °C
Operators Guide
16
Summary of Contents for BS110
Page 1: ...Operators Guide BS110 BS500 Bottle Samplers ...
Page 2: ......
Page 6: ...Operators Guide 4 ...
Page 8: ...Operators Guide 6 ...
Page 11: ...OPERATOR S GUIDE Operators Guide 9 ...
Page 22: ...Operators Guide 20 ...
Page 32: ...Operators Guide 30 ...
Page 35: ......