NPort 5200 Series User’s Manual
Web Console Configuration
5-29
IP address changed
The user has changed NPort 5200’s IP address. When the IP address changes, NPort 5200 will
send an e-mail with the new IP address before NPort 5200 reboots. If the NPort 5200 is unable to
send an e-mail message to the mail server within 15 seconds, NPort 5200 will reboot anyway, and
abort the e-mail auto warning.
Password changed
The user has changed NPort 5200’s password. When the password changes, NPort 5200 will send
an e-mail with the password changed notice before NPort 5200 reboots. If the NPort 5200 is
unable to send an e-mail message to the mail server within 15 seconds, NPort 5200 will reboot
anyway, and abort the e-mail auto warning.
DCD changed
The DCD (Data Carrier Detect) signal has changed, also indicating that the modem connection
status has changed. For example, a DCD change to high also means “Connected” between local
modem and remote modem. If the DCD signal changes to low, it also means that the connection
line is down.
When the DCD changes, NPort 5210/5230 will immediately send an e-mail or send an SNMP trap.
DSR changed
The DSR (Data Set Ready) signal has changed, also indicating that the data communication
equipment’s power is off. For example, a DSR change to high also means that the DCE is powered
ON. If the DSR signal changes to low, it also means that the DCE is powered off.
When the DSR changes, NPort 5210/5230 will immediately send an e-mail or send an SNMP trap.
Setting
Factory Default
Necessity
Enable, Disable
Disable
Optional
This feature helps the administrator manage how the NPort 5200 sends e-mail to pre-defined
e-mail boxes when the enabled events—such as Cold start, Warm start, Authentication failure,
etc.—occur. To configure this feature, click on the Event Type Mail checkbox.
Trap
Setting
Factory Default
Necessity
Enable, Disable
Disable
Optional
This feature helps the administrator manage how the NPort 5200 sends SNMP Trap to a
pre-defined SNMP Trap server when the enabled events—such as Cold start, Warm start,
Authentication failure, etc.—occur. To configure this feature, click on the Event Type Trap
checkbox.
ATTENTION
DCD changed
and
DSR changed
events are only supported by RS-232 ports (ports 1 and 2 for
NPort 5210, and port 1 for NPort 5230). Since NPort 5232 and NPort 5232I do not have RS-232
ports, the
DCD changed
and
DSR changed
options will not appear in the
Event Type
screen.