MD-124 HW Manual
Introduction
1-4
Compass Safe Distance:
<80cm (to be tested by DNV)
Green Product:
RoHS, cRoHS, WEEE
Warranty
Warranty Period:
One year
Details:
See www.moxa.com/warranty
We recommend taking the following precautions to minimize heat build-up within the display:
•
Position the display within ±40° of the vertical
•
If:
(a) the display is not positioned within ±40° of the vertical, or
(b) the operating temperature exceeds 25°C, or
(c) the display is used in a location with minimal ventilation,
then install an external fan to increase airflow upwards through the chassis
Important Safety Precaution:
Even though the display is rated to operate within the IEC 60945 standard of -15 to 55°C for industrial
applications, it is best to ensure that the operating temperature does not exceed 25°C. Doing so will
significantly increase the lifespan of your display and reduce service costs.