EDS-508A/505A Series User’s Manual
Featured Functions
3-89
NOTE
The following events will be recorded into the EDS-508A/505A’s Event Log table, and will then
be sent to the specified Syslog Server:
1.
Cold start
2.
Warm start
3.
Configuration change activated
4.
Power 1/2 transition (Off
On), Power 1/2 transition (On
Off)
5.
Authentication fail
6.
Topology changed
7.
Master setting is mismatched
8.
DI 1/2 transition (Off
On), DI 1/2 transition (On
Off)
9.
Port traffic overload
10.
dot1x Auth Fail
11.
Port link off / on
Using HTTPS/SSL
To secure your HTTP access, the EDS supports HTTPS/SSL to encrypt all HTTP traffic. Perform
the following steps to access the EDS’s web browser interface via HTTPS/SSL.
1.
Open Internet Explorer and type
https://EDS-508A/505A’s IP address
in the address field.
Press Enter to establish the connection.
2.
Warning messages will pop out to warn the user that the security certificate was issued by a
company they have not chosen to trust.