Ps34001b_oi_e.doc / 19.11.15
Page 33 / 43
8.3
Display of Actual Values
During normal operation it is possible to display an actual value. Two LEDs at the front panel
indicate the actual value displayed. You can scroll the actual value on the display by Scroll
Display command, which can be assigned either to a key or to an input. Parameter F08.071
“Default Display” selects the actual value to be displayed after power up of the unit.
Nr. Display
L1 (red)
L2 (yellow)
0 Display OFF (only two decimal points are lit to indicate
operation state)
OFF
OFF
1 Position error (differential counter)
OFF
OFF
2 Position error (bar graph display, see diagram below)
OFF
OFF
3 Actual frequency (Hz)
ON
OFF
4 Actual position in encoder increments
OFF
ON
8 Batch Counter (Incremented by each positioning
operation; can be reset to zero by the command “Clear
Batch Counter”)
ON
ON
Slave lags Master
Slave leads Master
-4 ... 0 ... +4
+5 ... +8
+9 ... +16
+17 ... +32
+33 ... +64
> +64
Bar graph display with reference to the actual position error
The diagram shows positive errors only (Slave lags position set-point). Negative errors are mirror-inverted
.