Fm210_01b_oi_e.docx / Nov-20
Page 15 / 40
Input Menu
Nr. Parameter
Adjustment range Default
025
Input 1 Config:
Defines the input behavior
0: Static Low, Function triggering at a "low" state
1: Static High, Function triggering at a "high" state
0 - 1
0
026
Input 1 Function:
0: No Function
1: Reset Edge
2: Inhibit
3: Direction
4: Jog
5: Offset Edge
6: Reference
7: Trim+
8: Trim-
9: Prestop Mark
10: Edge Prestop
11: Reset Static
12: Z Reference
0 - 12
0
027
Input 2 Config:
see Input 1 Config
0 - 1
0
028
Input 2 Function:
see Input 1 Function
0 - 12
0
029
Input 3 Config:
see Input 1 Config
0 - 1
0
030
Input 3 Function:
see Input 1 Function
0 - 12
0
031
Input 4 Config:
see Input 1 Config
0 - 1
0
032
Input 4 Function:
see Input 1 Function
0 - 12
0