Fm210_01b_oi_e.docx / Nov-20
Page 13 / 40
Parameter
Factor Menu
Nr. Parameter
Adjustment range Default
000
Factor 1:
Proportional factor of the pulse ratio.
f out = (F1 x f in) / F2
0,0001 - 9,9999
1,0000
001
Factor 2:
Reciprocal factor of the pulse ratio.
f out = (F1 x f in) / F2
0,0001 - 9,9999
1,0000
002 Reserved
Command Menu
Nr. Parameter
Adjustment range Default
003
Ref. Speed High:
This parameter is only valid in Reference mode.
It indicates the frequency in Hz at high speed.
1
–
1 000 000
4 000
004
Ref. Speed Low:
This parameter is only valid in Reference mode.
It indicates the frequency in Hz at low speed.
1
–
1 000 000
2 000
005
Ref. Ramp:
This parameter is only valid in Reference mode.
It indicates the ramp time in seconds. (0 = ramp off).
0 - 99
10
006
Jog Speed:
This parameter is only valid in Jog mode.
It indicates the Jog frequency in Hz.
1
–
1 000 000
1 000
007
Jog Ramp:
This parameter is only valid in Jog mode.
It indicates the ramp time in seconds. (0 = ramp off).
0 - 99
10
008
Trim Speed:
This parameter is only valid in Trim mode.
It indicates the duration in seconds for the inserted Trim pulses.
0,000
–
5,000
0,020
009
Offset:
This parameter is only valid in Offset mode.
It indicates the number of increments to be added.
-99 999
–
99 999
200
010
Special Mode:
This parameter has different properties depending on the parameter
setting and extends the functionality.
0 - 5
0
011 Reserved
012 Reserved