Fm210_01b_oi_e.docx / Nov-20
Page 40 / 40
Technical Specifications
Technical specifications:
Connections:
Connector type:
screw terminal, 1,5 mm² / AWG 16
Power supply:
Input voltage:
Protection circuit:
Ripple:
Consumption:
9 … 30 VDC
reverse polarity protection
≤
10 %
approx. 70 mA (at 9 V unloaded)
approx. 47 mA (at 30 V, unloaded)
Encoder supply:
Output voltage:
Output current:
5,5 VDC
24VDC (depending on supply voltage)
max. 250 mA
Incremental
inputs:
Number of inputs:
Channels:
Configuration:
RS422:
HTL Differential:
HTL Single Ended:
TTL:
3
A, B, Z (HTL Single Ended, TTL Single Ended)
A, /A, B, /B, Z, /Z (RS422, HTL Differential)
RS-422, HTL Differential, HTL Single Ended, TTL
max. 1 MHz (RS-422 Differential signal > 0.5 V)
max. 1 MHz (HTL Differential signal > 1 V)
max. 350kHz, Level 1: Low 0
…
10V, High 14
…
30 V
Level 2: Low 0
…
5V, High 9
…
30 V
max. 350kHz, Low 0 …
0.6V, High 2.2
… 5
V
Control
inputs:
Number of inputs:
Format:
Frequency:
Reaction time:
Load:
4
HTL, PNP (Low 0 … 4 V, High
10
… 30 V)
max. 1 kHz
1 ms
max. 5mA at 24VDC
Incremental
outputs:
Number of outputs:
Channels:
Format / level:
Output current:
3
A, /A, B, /B, Z, /Z
HTL: 8 … 29 V
(depend on supply voltage)
RS-422: 5 V
max. 30 mA / Push-Pull
Housing:
Material:
Mounting:
Dimensions
(B x H x T):
Protection class:
Weight:
Plastic
35 mm top hat rail (according to EN 60715)
22,5 x 102 x 102 mm
IP20
approx. 100 g
Temperature range:
Operation:
Storage:
0 °C … +60 °C
/ 32 … 140 °F
(not condensing)
-
25 °C … +70 °C
/ -13
… 158 °F
(not condensing)
Failure rate:
MTBF in years:
66,1 (long-term usage at 60 °C / 140 °F)
Conformity and
standards:
EMC 2014/30/EU:
RoHS (
Ⅱ
) 2011/65/EU
RoHS (
Ⅲ
) 2015/863:
EN 61326-1: 2013 for industrial location
EN 55011: 2017 / CISPR11: 2017 Class A
EN IEC 63000: 2018