Dz260_05a_oi_e.doc / Dez-16
Page 32 / 40
7.2.11.
Display –Menu
Display -Menu
Code Setting Range Default
Up-Date-Time
Update time of the LCD display (seconds)
„K4“
0.05...1.00
0.10
Display Mode
Scaling of the unit's engineering units and the actual LCD display
„K5“
0..4
0
0
Hz
1
kHz (switch points and analog output remain in Hz)
2
RPS (revolutions per second) = f / Encoder Factor (*)
3
RPM (revolutions per minute) = 60 x f / Encoder Factor (*)
4
Customer-specific units set by Encoder-Factor und Multiplier
Display = f x Multiplier / Encoder Factor (*)
Encoder Factor n
umber of impulses per revolution “
ppr”
(with Display-Modes 2 – 4 only)
„K6“
1..99999
1
Multiplier
Impulse multiplier (with display-Mode 4 only)
Display = f x Multiplier / Encoder Factor
„K7“
1..200
1
*) f = Input frequency in Hz
With display modes 2 – 4 also the switching point settings will use the same engineering units
as set for the display