Dz260_05a_oi_e.doc / Dez-16
Page 22 / 40
7.2.4.
Special-Menu
Special-Menu
Code Setting Range Default
Linear Mode
Programmable linearization for Basic Value and Analog Output
„B3“
0..2
0
0
Linearization off
1
Linearization range 0 V … +10 V
2
Linearization range -10 V … +10 V
Freq. Control
Defines behaviour and response of the unit to sudden interruptions of
the input frequency.
This parameter must only be changed in very special cases and under
special instruction of an motrona engineer.
Otherwise please use always the default setting "2"!
„B4“
0..2
2
Input Filter
Digital filter for limitation of the input frequency
„B5“
0..3
0
0
Filter off, the full range of frequency will be evaluated
1
Filter to cut frequencies higher than 500 kHz
2
Filter to cut frequencies higher than 100 kHz
3
Filter to cut frequencies higher than 10 kHz
Using the Input Filter will cause wrong frequency measurement when you use the unit with
frequencies higher than indicated above.
7.2.5.
Key-Pad-Menu
Key-Pad-Menu
(Passwords for menu groups)
Code
Setting Range
Default
Protect Menu 01 (
Preselect.-Menu
)
„C0“
0..999999
0
Protect Menu 02 (
Encoder-Menu
)
„C1“
Protect Menu 03 (
Ser.Readout.-Menu
)
„C2“
0 = no interlock
Protect Menu 04 (
Special-Menu
) a)
„C3“
6079
Protect Menu 05 (
Key-Pad-Menu
)
„C4“
1 – 999 999 =
Protect Menu 06 (
Command-Menu
)
„C5“
password for the
Protect Menu 07 (
Analog-Menu
)
„C6“
corresponding
Protect Menu 08 (
Serial-Menu
)
„C7“
group
Protect Menu 09 (
Switching-Menu
)
„C8“
Protect Menu 10 (
Linear-Menu
)
„C9“
Protect Menu 11 (
Display-Menu
)
„D0“
a) This menu is protected by the password 6079 due to factory setting. After entry of the
password please press the Enter button at least 2 seconds.