By340_04b_oi_e.doc / Apr-16
Page 21 / 42
The following schematics shows how in principle the parameter blocks are assigned to the
various elements and functions of the controller.
Master
Slave
Cont1
Cont2
Cont3
Cont4
Digital
Control
Inputs
RS232
K1 out
K2 out
K3 out
K4 out
Alert
Outputs
+/-10V
20 mA
Analogue
Outputs
P
ENT
F10
F04
F06 F09
F06
F06
F05
F07
up
dn
F08
F01
F03 F01
8.2.
Description of the Parameters
8.2.1.
Impulse Scaling
F01
Range
Default
F01.000 Factor 1: Impulse scaling factor for Master encoder. 0.00001 ... 9.99999 1.00000
F01.001 Factor 2: Impulse scaling factor for Slave encoder.
0.00001 ... 9.99999 1.00000
8.2.2.
Operational Settings
F02
Range
Default
F02.004 Operation mode (see table under section
6
)
1 … 8
1
F02.005 Trim Time:
Rate of change, to be entered as a number of
cycles (1 cycle = 250 µs), for phase trimming, when
the +/- Trim command are activated
0 … 9999
0000 = Trim off
0001 = fast change
9999 = slow change
10
F02.006 Integration Time:
Time constant for the phase integrator, which
avoids positional errors, also to be entered as a
number of cycles (1 cycle = 250 µs)
0 … 9999
0000 = Integrator off
0001 = fast speed
9999 = slow speed
0