Maintenance Procedures
The following maintenance procedures should be performed on a routine basis:
1. Carefully clean the exterior with a soft cloth to keep the cabinet looking new. Check the cabinet for dents
or impact markings, if found, inspect for damaged components.
2. Check all hoses and wires for cuts or frays.
3. Clean the filter screens after every 100 services or 6 months, which ever comes first. See the next sec-
tion for procedure.
Replacing Unit’s Internal Inline Filters
1. Disconnect power harness from any power source. Remove the Phillips head screws that join the top
cabinet housing to the lower housing. Remove the cap from the tank and carefully tip the top cabinet
forward.
2. Locate the 2 metal inline filters located near the front of the cabinet. Unscrew worm gear hose clamps,
remove and replace both filters. Ensure flow direction is for the filter is correct. Both filters the arrow
should be pointing towards the center of the machine.
3. Assemble in reverse order. NOTE: Use caution not to pinch O-ring on reassembly
4. Enter initials, date, and a check mark in the appropriate boxes of the Maintenance Record at the end of
the chapter.
10