Error Alerts
The TransTech™ III+ has been designed to stop the service and alert the operator in certain instances if the
unit is not functioning properly. See below for details.
TransTech™ In-line System Adapters
The TranTech™ III+ Part# 500-1100B includes two up-graded adapter kits:
1. Part# 200-3100A Adapter Kit TransTech™ (Standard)
2. Part# 200-3101A Adapter Kit TransTech™ (Deluxe)
LOW
VEHICLE
FLUID
LOW
CLEAN
FLUID
START ENGINE
STOP ENGINE
COMPLETE
SERVICE IN
PROGRESS
STOP
DRAIN
FLOW
DIRECTION
MODE
FILL
EMPTY
WASTE
AUTO
START /
RESUME
FLUID EXCHANGE
TransTech lII+
Alert
Notification
Cause
Hardware
Troubleshooting
steps
Recovery
Fill Error
See
Figure
Below.
The alarm sounds.
The following LEDs
flash: FILL.
There is a hardware or
software problem that
has caused the unit
to lose track of how
much fluid is in the
Clean Tank.
This alert prevents
the unit from overfill-
ing the transmission if
there is a problem with
the fluid level sensing
system.
Empty the Clean ATF
tank on the Trans-
Tech™ III+ before
attempting another
exchange.
Note: Do not leave oil
standing above the 0
line of the clean tank
for extended periods
of time. This may
cause the unit to lose
track of fluid levels.
Press STOP button to
silence the buzzer.
Due to the probability
of an overfill condition,
the unit cannot recover
from this error.
Reset the unit to
attempt further
operation.
12