Changing Fluid Types
9
Follow these steps if it is necessary to completely empty the clean fluid tank in order to
change to another type of fluid.
1. Install an open adapter in either red service hose. (Fluid will exit both hoses if adapters are installed in
both hoses). Place hose adapter into a capture container.
2. Connect power cord to a 12 volt DC source. Press and hold the START button for 5 seconds until the
alarm sounds. The FILL and DRAIN LEDs will flash.
3. Press & hold the FILL button. The pump will operate until the FILL button is released.
4. Tip the unit slightly backwards to let the fluid flow toward the back of the tank for complete evacuation.
5. Pressing the STOP button for five seconds will reset the unit.
Completely empty waste tank for shipping
1. Connect the power cord to a 12 volt DC source.
2. Direct the waste hose to a suitable disposal container. Open the ball valve on the end of the black waste
hose.
3. If the EMPTY WASTE LED is on, press the EMPTY WASTE button. The unit will automatically pump out
the waste fluid until the fluid level stops at the switch in the bottom of the tank. The EMPTY WASTE LED
will turn off.
ONLY FOLLOW STEPS 4-7 TO FULLY EMPTY UNIT FOR SHIPPING. INITIAL SETUP PROCEDURE
MUST BE PERFORMED IF WASTE TANK IS COMPLETELY EMPTIED.
4. Press and hold the EMPTY WASTE button for 5 seconds to enter MANUAL WASTE mode. Unit will
beep. Release the button. The EMPTY WASTE LED will flash.
5. Press and hold the EMPTY WASTE button. The pump will operate while the EMPTY WASTE button is
held down.
6. Tip the unit slightly backwards to let the fluid flow toward the back of the tank for complete evacuation.
7. Pressing the STOP button for five seconds will reset the unit.