[email protected] www.motorvac.com
Changing Fluid Types
Follow these steps if it is necessary to completely empty the clean fluid tank in order to
change to another type of fluid.
1. Install an open adapter in the clean hose coupler. Ensure direction switch is in position A. Install hose into
a capture container.
2. Connect power cord to a 12 volt DC source. Press the
MODE
button until both the Dipstick and Manual
LED’s are on.
3. Press & hold the
FILL
button. The pump will operate until the FILL button is released.
4. Tip the unit slightly backwards to let the fluid flow toward the back of the tank for complete evacuation.
5. Pressing the
STOP
button for five seconds will reset the unit.
Follow these steps if it is necessary to completely empty the dirty fluid tank.
1. Connect the power cord to a 12 volt DC source.
2. Direct the waste hose to a suitable disposal container. Open the ball valve on the end of the waste hose.
3. If the
EMPTY WASTE
LED is on, press the
EMPTY WASTE
button. The unit will automatically pump out
the dirty fluid until the fluid level stops at the switch in the bottom of the tank. The
EMPTY WASTE
LED
will go off.
4. Press and hold the
EMPTY WASTE
button for 5 seconds to enter
MANUAL WASTE
mode. Unit will
beep. Release the button. The
EMPTY WASTE LED
will flash.
5. Press and hold the
EMPTY WASTE
button. The pump will operate until the
EMPTY WASTE
button is
released.
6. Tip the unit slightly backwards to let the fluid flow toward the back of the tank for complete evacuation.
7. Pressing the
STOP
button for five seconds will reset the unit.
12