background image

Model Number Description

It is essential to check the VMX-Synergy Plus nameplate and make sure that the soft starter is properly 
sized for your AC motor. 

VMX-SGY-I-17-6-XX-XX 

Key Features 

Touchscreen 

User 

Interface 

Anybus 

Compact 

Com Port 

Future use 

USB Port 

Motor 

Connections 

Status LED 

Modbus RTU 

Port 

Expansion 

Port 

Supply 

Connections 

Control Terminals 

(Under cover) 

Ground 

Connection 

Keypad 

release point 

Keypad 

release point 

Option 

Non-critical customer options 
(may be blank) 

Control supply U

s

 

01 

– U

s

 = 24Vdc, 110VAC or 230VAC 

02 

– U

s

 = 110VAC 

03 

– U

s

 = 230VAC 

Main Supply voltage 

– 200VAC to 600VAC, U

600V 

Model rating designation 

VMX-SGY-I-17 to VMX-SGY-I-500 

Summary of Contents for VMX-Synergy Plus VMX-SGY-I-100

Page 1: ......

Page 2: ...rreur progressif doit tre int gralement v rifi par un agent de maintenance agr Important information Installers should read and understand the instructions in this guide prior to installing operating...

Page 3: ...ce de protection minimal It is the responsibility of the installer to provide suitable grounding and branch circuit protection in accordance with local electrical safety codes Il appartient l installe...

Page 4: ...act Com Port Future use USB Port Motor Connections Status LED Modbus RTU Port Expansion Port Supply Connections Control Terminals Under cover Ground Connection Keypad release point Keypad release poin...

Page 5: ...e 1 VMX SGY I 132 to VMX SGY I 195 Size 2 Dimensions Dimensions VMX SGY I 17 to VMX SGY I 29 Weight 3 9 kg 8 6 lbs VMX SGY I 35 to VMX SGY I 100 Weight 4 2 kg 9 26 lbs VMX SGY I 132 Weight 6 7 kg 14 7...

Page 6: ...stallation VMX SGY I 242 to VMX SGY I 361 Size 3 VMX SGY I 430 to VMX SGY I 500 Size 3 Dimensions Dimensions VMX SGY I 242 to VMX SGY I 361 Weight 17 0 kg 37 5 lbs VMX SGY I 430 to VMX SGY I 500 Weigh...

Page 7: ...m2 10AWG 8 71 VMX SGY I 55 to VMX SGY I 80 10mm2 8AWG VMX SGY I 100 16mm2 6AWG M8 stud VMX SGY I 132 to VMX SGY I 160 16mm2 6AWG 12 106 VMX SGY I 195 25mm2 4AWG VMX SGY I 242 35mm2 3AWG VMX SGY I 302...

Page 8: ...s x number of starts per hour 1200 iERs Disabled Watts VMX Synergy Plus VMX Synergy Plus current rating x 0 6 iERs Enabled The maximum power dissipation occurs when energy saving and the iERS is turne...

Page 9: ...9 Terminal Designations and Wiring Connection...

Page 10: ...30Vac or 24Vdc 230Vac factory default 230Vac d faut d usine 4 The system can have either a 110 230Vac mains or 24Vdc input NOT both Le syst me peut avoir soit une alimentation principale de 110 230Vac...

Page 11: ...re le court circuit dans la section Informations techniques normes du pr sent guide For wire size and torque requirements see Technical Information standards section of this guide Pour les dimensions...

Page 12: ...utes les configurations de c blage doivent galement tre en conformit avec les codes et les r glements locaux et nationaux en vigueur 2 Power factor correction capacitors must NOT be positioned between...

Page 13: ...13 Programming OL 0 0A P 0 1a 1b 2 3 4 5 6 7 8 9 Screen 1a on 1st Power On only Subsequent use will show 1b...

Page 14: ...5 100 VMX SGY I 132 6 01 132 37 75 90 125 40 40 40 100 125 VMX SGY I 160 6 01 160 45 90 110 156 50 50 60 125 150 VMX SGY I 195 6 01 195 55 110 132 192 60 60 75 150 200 VMX SGY I 242 6 01 242 75 132 16...

Page 15: ...Motor overload cold trip curves 20 C ambient Class10 Class20 Class30 Technical Information Fig 1 Trip curves Note When the overload has tripped there is a forced cooling time to allow the overload to...

Page 16: ...10VAC or 230VAC 50 60Hz 5Hz Protect with 4A UL 248 Listed fuse Rated control supply voltage Us See Rating Table 2 Amp supply cont Relay specification 11 12 24 and 33 34 44 AC 15 230VAC 1A DC 13 30VDC...

Page 17: ...40__ Bussmann 170M41__ Bussmann 170M42__ SIBA 20 61___ Fuse rating A 100 100 160 160 200 200 200 315 315 Size 2 and 3 Type designation eg VMX SGY I 132 160 195 242 302 361 430 500 Rated operational cu...

Page 18: ...0 30 55 55 99 30 30 30 75 100 SGY I 100 SGY I 132 SGY I 160 132 37 75 90 125 40 40 40 100 125 SGY I 132 SGY I 160 SGY I 195 160 45 90 110 156 50 50 60 125 150 SGY I 160 SGY I 195 See Size 3 195 55 110...

Page 19: ...ize 3 338 90 185 220 312 100 100 125 250 300 SGY I 195 See Size 3 See Size 3 Size 3 Ie 1 kW FLA 1 Hp Trip Class 10 Trip Class 20 Trip Class 30 A 230V 400V 500V A 200V 208V 220 240V 440 480V 550 600V I...

Page 20: ...ostrokovnjaki in elektrotehni no pou ene osebe Nebezpe enstvo ohrozenia ivota elektrick m pr dom Pr ce ktor s ni ie op san sm vykon vat iba elektroodborn ci a osoby s elektrotechnick m vzdelan m Perig...

Page 21: ...21 Notes...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Page 24: ......

Reviews: