Wiring Connection
3 Wire Control Diagram
3 Wire Control Diagram
110/230Vac control supply (U
s
)
24Vdc control supply (U
s
)
and digital input (U
c
) programming.
and digital input (U
c
) programming
.
(VMX-SGY-I-17 to VMX-SGY-I-361)
L
N
D1-1I
D1COM
D1-2I
D2COM
D2-1I
53
54
FU1
EMERGENCY STOP
110/230VAC
STOP
START
RESET
N
(OPTIONAL)
LINE ISOLATION
CONTACTOR
K1
24VDC
0VDC
D1-1I
D1COM
D1-2I
D2COM
D2-1I
53
54
FU1
24VDC
0V
LINE ISOLATION
CONTACTOR
STOP
START
RESET
(OPTIONAL)
EMERGENCY STOP
K1
CAUTION
#1
REFER to TABLE 1 on page 11 for input control voltages.
These recommended wiring diagrams are specifically where the control supply voltage (US) is identical to
the control circuit voltage (UC) and not to be supplied separately. Other wiring configurations must also be
in accordance with existing local and national codes and regulations.
RÉFÉRER au TABLEU 1 à la page 12
pour des tensions de contrôle d’entrée.
Ces schémas de câblage sont recommandées spécifiquement lorsque la tension d’alimentation de
commande (US) est identique à la tension du circuit de commande (UC). US et UC ne doivent pas être
alimentés séparément. Toutes les configurations de câblage doivent également être en conformité avec les
codes et les règlements locaux et nationaux en vigueur.
#2
Power factor correction capacitors must NOT be positioned between the soft start and the motor or there is
a risk of damaging thyristors due to current peaks.
Condensateurs de correction de facteur de puissance NE doivent pas être placés entre le moteur at le
démarreur progre
ssif ou il y a un risqué d’endommager les thyristors en raison des pics de courant.
110/230Vac (US) and (UC) user programmable
24Vdc (US) and (UC) user programmable
control diagram
control diagram (VMX-SGY-I-17 to VMX-SGY-I-361)
L
N
D1-1I
D1COM
D1-2I
D2COM
D2-1I
53
54
FU1
110/230VAC
N
LINE ISOLATION
CONTACTOR
K2
K2
RESET
STOP
START
(OPTIONAL)
EMERGENCY STOP
K1
K2
24VDC
0VDC
D1-1I
D1COM
D1-2I
D2COM
D2-1I
53
54
FU1
24VDC
0V
LINE ISOLATION
CONTACTOR
RESET
K2
STOP
START
(OPTIONAL)
EMERGENCY STOP
K1
K2
K2
User programmable inputs are full programmable
1) Optional high reset. If this reset is required ensure “User
Programmable” is selected in the control method menu found
in the Digital Inputs menu. If you would prefer the reset to work
by removing and reapplying the Start Signal on D1 - 1I then
select “Two wire control” in the control method menu.
D1
– 1I = High Start / Low Stop
D1
– 2I = None
D2
– 1I = High Reset
Summary of Contents for VMX-Synergy Plus VMX-SGY-I-100