OPERATION
68EVB912B32UM/D
3-14
BAUD
Set Baud Rate
BAUD
syntax:
BAUD <BAUDRate>
where:
<BAUDRate>
is an unsigned 16-bit decimal number.
The BAUD command is used to change the communications rate of the SCI used by D-Bug12 for
the terminal interface.
restrictions:
Because the <BAUDRate> parameter supplied on the command line is a 16-bit unsigned integer,
BAUD rates greater than 65535 baud cannot be set using this command. The SCI BAUD rate
divider value for the requested BAUD rate is calculated using the E-clock value supplied in the
D-Bug12 customization data area. Because the SCI BAUD rate divider is a 13-bit counter,
certain BAUD rates may not be supported at particular E-clock frequencies. If the value
calculated for the SCI’s BAUD rate divider is equal to zero or greater than 8191, command
execution is terminated and the communications BAUD rate is not changed.
example:
>BAUD 50
Invalid BAUD Rate
>BAUD 38400
Change Terminal BR, Press Return
>
Summary of Contents for M68EVB912B32
Page 8: ...CONTENTS 68EVB912B32UM D viii ...
Page 11: ...GENERAL INFORMATION 68EVB912B32UM D 1 3 Figure 1 1 EVB Layout and Component Placement ...
Page 22: ...CONFIGURATION AND SETUP 68EVB912B32UM D 2 6 ...
Page 80: ...OPERATION 68EVB912B32UM D 3 58 ...
Page 90: ...HARDWARE REFERENCE 68EVB912B32UM D 4 10 ...
Page 102: ...COMMUNICATIONS PROGRAM EXAMPLES 68EVB912B32UM D B 8 ...
Page 106: ...D BUG12 STARTUP CODE 68EVB912B32UM D C 4 ...
Page 112: ...D BUG12 CUSTOMIZATION DATA 68EVB912B32UM D D 6 ...
Page 122: ...INDEX 68EVB912B32UM D 4 ...