PREPARING FOR FIELD LEVEL TESTING:
Using RSS
44
68P80401P05
•
Do not wear nylon clothing when handling any printed-circuit board.
•
Prior to touching any printed-circuit board, touch an electrical ground to remove any static
charge that might have accumulated.
Refer to Service and Repair Note SRN-F1052 for more information. This note is available through:
Motorola Literature Distribution Center
2290 Hammond Drive
Schaumburg, IL 60173
847-576-2826
The following should be considered when storing or transporting a circuit board:
•
Place the printed-circuit board in conductive, anti-static material.
•
Do not insert the printed-circuit board into conventional plastic “snow” trays used for
transporting other devices.
7.2
Using RSS
Use
Radio Service Software (RSS)
to program a new software version or to update user information
in the codeplug. Refer to “Connecting the Unit to the RSS Workstation” and the
Radio Service
Software User’s Guide
for information on the setup and use of RSS.
NOTE:
You can use the RSS online Help for locating specific information about RSS dialog boxes
and fields. To access online Help, press
F1
while you are viewing an RSS screen.
If you are using the R-2660A Communications System Analyzer in the
i
DEN mode, which is 6:1
capable, use RSS to program an
i
580 unit for
Full Rate
operation. Use the
6:1 Interconnect
softkey
for all interconnect testing.
If you are using the R-2660B or later, which is 3:1 capable, use RSS to program an
i
580 unit for
Half Rate
operation. Use the
3:1 Interconnect
softkey for all interconnect testing.
In the carrier version of RSS (but not the agent version), you can change interleave values. To access
the fields where you can change these interleave values, go to the User Ergonomics dialog box, and
then click on the
Interleave
tab.
NOTE:
After servicing a unit, use RSS to reprogram the unit back to its original operating state.
Refer to the
R-2660 Digital Communications System Analyzer Operator’s Manual
for more
information on how to set up this equipment for
i
DEN mode testing.
7.3
Connecting an
i
DEN Unit to the R-2660
The R-2660 Communications System Analyzer enables you to monitor and perform tests on
i
DEN
units. Figure 7-1 shows a typical R-2660 test setup.
Equipment Required:
R-2660, reference SIM card, SMA to N-type RF coaxial cable, battery
eliminator, 5.0-12.0 Vdc power supply.