GSM-204-423
Suggested RF configurations
31st Oct 01
Inst. 3–54
Installation & Configuration: Horizon
macro outdoor
CONTROLLED INTRODUCTION
68P02902W03-A
Configuration
for sector 5/5/5
or 6/6/6
Figure 3-31 shows a suggested configuration, using three Horizon
macro
cabinets, for sector 5/5/5 or sector 6/6/6 with dual stage duplexed combining
filter and air combining.
CABINET 2
CABINET 3
CABINET 1
(master)
Figure 3-31 Sector 5/5/5 or sector 6/6/6 with DDF and air combining
Unused SMA connectors must be fitted with 50 ohm terminating loads as shown
below.
If configured for...
Then 50 ohm load required on
unused SMA input to...
sector 5/5/5
all DDF 2 modules
3/3/3 (depopulated 6/6/6)
all Tx modules from
radio slots 1, 3, and 5