A p p l i c a t i o n V i e w s
S u p p o r t e d A p p l i c a t i o n s
D e v i c e M a n a g e m e n t
Page 82
M o t o r o l a V a n g u a r d
a positive number for the “Output Signal Level”
will result in the DSPM card amplifying the signal
by that many dB.
FaxSupport
Selects whether the FAX data is to be supported.
Valid values are:
disabled
,
enabled
, and
nc
.
FaxRates
The speed to switch to, when FAX data is
detected. This parameter is ignored if Fax support
was disabled. Valid values are:
fr9600
,
fr4800
,
and
nc
.
BandDetect
Modem data detection. Valid values are:
yes
,
no
,
and
nc
. This parameter will be skipped in normal
mode, and displayed only when DEBUG is turned
on.
AutoCallMnemoni
This mnemonic name is used to originate the call.
It consists of 0 - 8 alphanumeric characters.
CallControl
Select calling method.
Table 29
displays the valid
methods and descriptions:
AutoCallTimeout
Time interval between two successive calls in case
of failure of previous call. Used only in “Auto” call
control mode. This parameter will be skipped if
CallControl
is “Offhook” or “Switched.”
CallRetries
Enter maximum number of call retries when
previous call failed. Used only in Auto Call
Control mode. The value
0
means try forever. This
parameter will be skipped if
CallControl
is
“Offhook” or “Switched.”
Table 29:
Calling Methods
Method
Description
offhook
Call only when Offhook. Disconnect on
Onhook.
auto
SVC does not depend on On/Offhook
condition. It remains established
permanently after the power-up.
switched
Call only when interface goes offhook
and disconnect call when interface goes
onhook. Destination is determined by
the DTMF digits received.
nc
Skipped during configuration.