On the Illustrated diagrams below and on the next page, are the 

dimensions for the installation

 of the automated system.

INTERIOR OPENING INSTALLATION QUOTAS

04. INSTALLATION

* The installation of opening stopper is not mandatory.

Legend:
Dimension X 

- Horizontal distance between hinge axis of the door and the axis axle of the motor.

Dimension Y

 - Vertical distance between hinge axis of the door and the axis axle of the motor.

Dimension W

 - Distance between axis of the motor brackets.

When installing the automation, it is mandatory to respect the dimensions x and 

y, indicated in the tables. Within this area, it is possible to identify the maximum 

opening angle that the gate reaches in these dimensions.

X

Y

 and 

W

 shown in (mm)

It is very important that these dimensions are respected!

 Only this way can be assured

the correct functioning and durability of the motors!

JAG 400

Dimension 

Y

Dimension 

X

180

190

200

210

190

100º

96º

94º

91º

200

96º

93º

91º

-

210

93º

90º

-

-

220

90º

-

-

-

W

 1295 to 1300

JAG 600

Dimension 

Y

Dimension 

X

210

220

230

240

250

260

270

280

290

300

320

340

360

380

250

98º

100º

103º

105º

107º

109º

109º

106º

104º

101º

98º

95º

93º

91º

260

98º

100º

102º

104º

107º

108º

106º

104º

101º

99º

96º

93º

91º

-

270

98º

100º

102º

104º

106º

107º

104º

101º

99º

97º

94º

92º

-

-

280

98º

100º

102º

104º

106º

104º

101º

99º

97º

95º

92º

-

-

-

290

98º

100º

102º

104º

104º

101º

98º

96º

95º

93º

91º

-

-

-

300

98º

100º

102º

103º

101º

98º

96º

94º

93º

91º

-

-

-

-

320

97º

99º

100º

98º

95º

93º

92º

90º

-

-

-

-

-

-

340

97º

97º

94º

92º

91º

-

-

-

-

-

-

-

-

-

360

93º

91º

-

-

-

-

-

-

-

-

-

-

-

-

W

 1695 to 1700

(EXTERIOR)

(INTERIOR)

Axis of rotation of the

motor, on the rear support

Opening

direction

Axis of rotation of the gate

(center of the door hinge) 

Axis of rotation of the

motor, on the front bracket

Closing mechanical

stopper

*Opening mechanical stopper

Summary of Contents for JAG400

Page 1: ...V6 2 REV 05 2022 JAG EN USER S AND INSTALLER S MANUAL...

Page 2: ...untries with recycling systems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be dispo...

Page 3: ...with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorize...

Page 4: ...and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or r...

Page 5: ...kage JAG specifications are as follow 01 02 03 JAG400 JAG600 Power Supply 230V 230Vac 50 60Hz 230Vac 50 60Hz 110V 110Vac 50 60Hz 110Vac 50 60Hz 24V 24Vdc 24Vdc Power 230 110V 300W 300W 24V 80W 80W Cur...

Page 6: ...B Vertical distance from the floor to the top of the front support Set dimension A this can be any size of your choice After you set dimension A subtract 20mm to find dimension B It is very important...

Page 7: ...It is very important that these dimensions are respected Only this way can be assured the correct functioning and durability of the motors JAG 400 Dimension Y Dimension X 180 190 200 210 190 100 96 94...

Page 8: ...pports from motor Axis of rotation of the gate center of the door hinge Axis of rotation of the motor on the front support Closing mechanical stopper Axis of rotation of the motor on the rear support...

Page 9: ...to stretch retract arm easily see page 4A to get the correct po sition for supports Install the pins removed earlier on each side with a small amount of lubricant for less friction Unlock the motor an...

Page 10: ...he gate to the open position 07 Loosen the screw shown in the image 24 so that it is possible to move the micro switch in the profile 08 Adjust the closure micro switch B until it makes click on the p...

Page 11: ...rtant to use mechanical stoppers in the opening and closing position of the gate If not respected components of the automation may suffer efforts for which they were not prepared and as a result will...

Page 12: ...on the micro s If it does not operate replace with a new 24V motor and re test to ensure that all is ok To detect which are the components with problems in a 24V JAG automatism installation it is nece...

Page 13: ...or Motor Motor Motor Black Black Gray Gray Brown Brown COM COM Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply AUTOMATION AUTOMATION Ground Wire Ground Wire Ground Wire G...

Page 14: ...oth remove the ex cess leaving a homogeneous layer of lubri cant over the arm Place a small amount of lubricant on the holes that contains support pins Check motor supports Make sure that supports rem...

Page 15: ...board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagno...

Reviews: