9A
9B
B
A
B
A
17
18
19
20
21
22
23
24
25
26
EN
EN
01
• Unlock the motor (see page 4A).
02
• Loosen the 3 front screws, remove the cover and the profile cover.
03
• Take the gate to the closed position.
04
• Loosen the screw shown in the image (21), so that it is possible to move the micro-switch in
the profile.
05
• Adjust the closure micro-switch (A) until it makes “click” on the pressure piece. Tighten the
screw to secure the micro in that position.
06
• Take the gate to the open position.
07
• Loosen the screw shown in the image (24), so that it is possible to move the micro-switch
in the profile.
08
• Adjust the closure micro-switch (B) until it makes *click* on the pressure piece. Tighten the
screw to secure the micro in that position.
A
• The Closing Micro-Switch.
B
• The Opening Micro-Switch.
09
• Test the door manually and
if necessary readjust the micros,
as indicated in the previous
paragraphs.
10
• When finished, place the
profile cover and the plastic
cover.
11
• Repeat the whole process
for the other motor.
04. INSTALLATION
MICROS ADJUSTMENT
04. INSTALLATION
MICROS ADJUSTMENT
Example of the gate with inside opening